When the Bureau of Indian Standards issued the 2005 edition of the National Building Code, the office chapter of its acoustics section opened with a sentence any facility head can still test on a Monday morning: "Modern office buildings are often noisier than older buildings due to the use of thinner and more rigid forms of construction, harder finishes, more austere furnishings and use of business machines." The list of indoor noise sources a few lines further on starts with office machines "such as typewriters". The diagnosis has aged better than the equipment.
That code set its office limits in seconds of reverberation, and a reverberation time can be converted into a headcount. That is the argument of this piece: how many people can hold a proper conversation in a room is decided by its reverberation first and its seating plan second, whether the room is a staff cafeteria, a restaurant or an open-plan floor. Measure the reverberation before choosing any panel, and the choice of panel follows from the measurement.
Which edition of the code to read
The National Building Code is published by the Bureau of Indian Standards as SP 7 and serves as a model code for agencies that regulate construction. Acoustics lives in Part 8, Building Services, Section 4, "Acoustics, Sound Insulation and Noise Control". The current edition is NBC 2016, and BIS has circulated a draft revision of that section for study and comment. The 2005 text quoted above is no longer the edition in force, so take the reverberation limits for offices and canteens from the edition your project is approved under, and have your acoustic consultant write them into the specification.
Turning a reverberation limit into a headcount
T is the time it takes for a sound in the room to fade out, expressed in seconds. The rule that turns it into people comes from Jens Holger Rindel, who calls the result acoustic capacity: the headcount at which pairs sitting one metre apart can still converse at a sufficient level. Capacity ≈ V / 20T, where V is the volume in m³ and T the reverberation time, taken in the empty but furnished room for the mid range, 500 Hz up to 1000 Hz.
Sufficient, on his scale, means the room's background stays at or below 71 dB, even when your colleague's voice is 3 dB quieter than the surrounding noise. Satisfactory conditions need the room below half its capacity. People with mild hearing loss, or talking in a language that is not their first, need roughly 3 dB of extra margin, a point worth remembering in workplaces where meetings switch between languages.
Here is the rule applied to three rooms at three reverberation times:
A 150 m³ meeting room or small cafeteria: 5 people at 1.4 seconds, 7 at 1.0 second, 10 at 0.7 second.
A 300 m³ canteen or restaurant: 10 people at 1.4 seconds, 15 at 1.0 second, 21 at 0.7 second.
A 600 m³ dining hall or open-plan floor: 21 people at 1.4 seconds, 30 at 1.0 second, 42 at 0.7 second.
At 1.4 seconds, the 600 m³ hall supports sufficient conversation for one person per 28 m³ of air. Seat a hundred people for lunch there and the room is working at nearly five times its capacity.
Rindel found the same pattern in practice. One restaurant in his 2012 table, 412 m³ with 100 seats and a reverberation time of one second, had an acoustic capacity of 21. Two halls of nearly equal volume (2,485 and 2,495 m³) reached 50 and 156, at 2.5 and 0.8 seconds. His recommendation: seating no more than a quarter above capacity, and the figure posted at the door.
The loop that makes a full room louder
A busy room climbs in volume for a reason with a name. Lombard reported in 1911 that people speak louder in noise. In Rindel's reading of the measurements, from about 45 dB of background upward, the voice climbs by roughly 1 dB for every 2 dB of added noise. Each group raises its voice over the others, the overall level goes up, and everyone raises their voice again, a feedback situation in Rindel's words. In 1959 MacLean described a ceiling on guests for a quiet party, beyond which it turns loud.
Picture a table seating ten. To speak to someone on the far side, roughly two metres off, the room must stay at or under 59 dB, Rindel calculates; once it reaches 77 dB, conversation shrinks to the chair next to yours.
Open-plan desks, phone calls and memory
The office version of the problem has been measured too. Banbury and Berry surveyed 88 office workers across two sites (Ergonomics, 2005): nearly all of them, 99%, found their concentration impaired by office noise, particularly phones left to ring at unoccupied desks and colleagues' background conversations, with no sign that they got used to it.
In a 2011 experiment by Jahncke's group, the same 47 students worked through a 39 dB session and a 51 dB session of office background sound, two hours each. At 51 dB they recalled fewer words, skipped more answers, and reported more fatigue and weaker motivation; the other tests showed no change. Those who spent the break watching video footage of a flowing river, sound included, said they had more energy, while a break spent in office noise did more damage to motivation.
The costly sound is speech you can understand. The same researcher's later studies found performance falling as background speech became more intelligible: to do no harm, the STI must sit below 0.50. Under ISO 3382-3:2022, which measures open-plan offices while they are empty, the distraction distance is the point at which a speaker's STI drops below that threshold, together with the spatial decay rate: the dB a voice sheds when the distance from it doubles. Read together, they show how far a voice carries across that particular floor.
For calls and one-to-one discussions that a floor plan cannot separate, soundproof pods give the conversation its own enclosed space.
Sound changes how food tastes
For anyone running a restaurant or a corporate dining hall, there is one more reason. Woods and colleagues (2011, Food Quality and Preference), working with Unilever, had blindfolded people taste food while listening, through headphones, to silence or to white noise at a low or high level. The high level made sweetness and saltiness seem weaker and crunchiness stronger. Yan and Dando (2015) found that sound simulating an aircraft cabin lowered sweetness and raised umami for 48 participants, leaving salty, sour and bitter unchanged.
A field survey of 112 restaurants in Singapore by Lindborg (2015) found that the more expensive the menu, the less loud the restaurant. In Berlin, Steffens and colleagues (2021) found that sound level and soundscape pleasantness predicted how 142 diners in twelve restaurants rated overall quality. Neither study measured whether diners return.
A checklist for the MD and the architect
One distinction first. Sound-absorbing panels remove sound energy inside a room and shorten its reverberation. Insulation is the other job: keeping sound inside its own room, a matter for partitions and slabs, with requirements of its own. Absorption is tested under ISO 354 and expressed as a single value, αw, under ISO 11654, with classes from E up to A (A absorbs most). Treat the class as approximate and read the αw value on the data sheet together with the area covered.
1. Volume, in m³.
2. T, the reverberation time, taken with the furniture installed and nobody inside, 500 Hz to 1 kHz, by a qualified acoustician.
3. Busiest-hour occupancy, and whether people are eating together, on the phone or doing desk work.
4. The reverberation you need, from V / 20T: for 42 people to converse in 600 m³, about 0.7 second.
5. αw and the panel area needed to reach it.
With those five numbers the design work becomes the pleasant part, because acoustic products are also chosen by eye. Within the acoustics and focus selection in our catalogue, αw makes the shortlist and personal taste the final pick. For a project with us, the opening data are the room's volume and its reverberation measurement.
When the edition that governs your project gives a reverberation limit for the canteen, it gives a number of seconds. Run V / 20T on it and you have the canteen's real seating plan for conversation.
In brief
Where does the National Building Code of India deal with acoustics?
In Part 8, Building Services, Section 4, "Acoustics, Sound Insulation and Noise Control". The current edition is NBC 2016 (SP 7:2016), and BIS has circulated a draft revision of that section for comment, so take reverberation limits from the edition your project is approved under, not from the 2005 text.
What is a sensible headcount for an office canteen?
Following Rindel's acoustic capacity, divide V (m³) by 20 multiplied by T. A 600 m³ canteen at 1.4 seconds allows sufficient conversation for about 21 people; at 0.7 second, about 42.
Why is open-plan office noise tiring?
A 2011 study (Jahncke et al.) found that two hours of office sound at 51 dB, against 39 dB, cut word recall and left participants more fatigued and less motivated; other tests did not change. Understandable speech does the damage, so aim for an STI below 0.50.
Is sound absorption the same as soundproofing?
They are different jobs. Absorbing panels cut the reverberation within a space and are rated by αw under ISO 354 and ISO 11654; insulation deals with noise moving from one room to another through walls and floors.